Device recalls

CARDIOHELP-i System. Blood oxygenation and carbon dioxide removal system.

Maquet Medical Systems USA · The firm identified that the measured patient leakage current in some devices significantly exceeded expected levels.

Open, ClassifiedUnder Investigation by firmZ-1831-2024
Open FDA's page for this record
Cfres ID
207234
Product res number
Z-1831-2024
Event date initiated
2024-04-15
Event date posted
2024-05-16
Recall status
Open, Classified
Res event number
94450
Product code
DTQ
Product description
CARDIOHELP-i System. Blood oxygenation and carbon dioxide removal system.
Firm FEI number
3008355164
Recalling firm
Maquet Medical Systems USA
Address 1
45 Barbour Pond Dr
City
Wayne
State
NJ
Postal code
07470-2094
Additional info contact
Marc De Carlo 973-709-7725
Reason for recall
The firm identified that the measured patient leakage current in some devices significantly exceeded expected levels.
Root cause description
Under Investigation by firm
Product quantity
148 units (US: 5; OUS: 143)
Distribution pattern
US Nationwide distribution in the states of NJ & TX.
Code info

Part No. 70104.8012 and 70104.8012R; UDI-DI: 04037691658384; Serial no. 90410021, 90410029, 90410165, 90410254, 90410255, 90410024, 90410025, 90410026, 90410028, 90410030, 90410031, 90410034, 90410035, 90410036, 90410043, 90410044, 90410045, 90410046, 90410047, 90410048, 90410049, 90410050, 90410051, 90410052, 90410053, 90410054, 90410055, 90410056, 90410057, 90410058, 90410059, 90410060, 90410061, 90410062, 90410063, 90410064, 90410065, 90410067, 90410068, 90410069, 90410070, 90410071, 90410072, 90410073, 90410074, 90410075, 90410076, 90410077, 90410078, 90410079, 90410080, 90410081, 90410082, 90410084, 90410085, 90410086, 90410087, 90410088, 90410089, 90410091, 90410093, 90410094, 90410095, 90410096, 90410097, 90410098, 90410099, 90410100, 90410101, 90410102, 90410103, 90410104, 90410105, 90410106, 90410107, 90410108, 90410109, 90410110, 90410111, 90410112, 90410113, 90410114, 90410115, 90410116, 90410117, 90410118, 90410119, 90410120, 90410121, 90410122, 90410123, 90410124, 90410125, 90410126, 90410127, 90410130, 90410131, 90410132, 90410133, 90410134, 90410135, 90410136, 90410137, 90410138, 90410139, 90410140, 90410141, 90410142, 90410143, 90410144, 90410146, 90410147, 90410148, 90410149, 90410151, 90410152, 90410153, 90410154, 90410155, 90410156, 90410157, 90410158, 90410159, 90410160, 90410161, 90410162, 90410163, 90410166, 90410167, 90410168, 90410169, 90410170, 90410172, 90410173, 90410174, 90410175, 90410176, 90410177, 90410178, 90410179, 90410180, 90410181, 90410182, 90410183, 90410184, 90410185, 90410186, 90410187.

Action

Consignees received an "URGENT MEDICAL DEVICE - Removal" email, dated 4/15/2024, notifying them of this recall event. Consignees are asked to examine their inventory to identify if they possess any affected devices and all consignees are asked to return the provided Response Form via email to identify where affected devices are located. Consignees that report having any affected devices will be contacted by Getinge to arrange for return of the affected device to upgrade the system's sensor panel and perform testing to ensure that leakage current is within specifications. Technical Support can also be contacted at 888-943-8872 (option 4, option 2, option 1) Monday through Friday between 8:00 AM and 6:00 PM EST to make service arrangements. Consignees are asked to not use affected devices for any additional patients until it has been cleared by the MCP/Getinge system check, repaired, or replaced. The provided recall notice is to be forwarded to users of the CARDIOHELP-i system and if the device was further distributed.

K numbers
K133598
Harmonized identifiers (openFDA)
Device name
Console, Heart-Lung Machine, Cardiopulmonary Bypass
Medical specialty description
Cardiovascular
Regulation number
870.4220
Device class
2
K number
K060053, K103762, K080832, K133598, K813034, K862973, K770002, K221895, K210130, K772001, K052555, K801097, K090006, K915183, K093882, K153376, K851615, K871131, K190282, K011088, K092463, K151349, K020571, K842138, K863541, K964017, K942582, K173834, K091007, K232291, K870976, K131041, K163531, K943803, K002118, K221373, K021694, K022947, K863960, K030141 +12 more
Registration number
2184009, 3010163695, 2916596, 3006073153, 3009507273, 3002807090, 3007427881, 3005941719, 3001589655, 9611109, 1218444, 3019807891, 8010762, 9680841, 1828100, 3042990265, 3010703925
FEI number
3010163695, 2916596, 3006073153, 3006003617, 3007427881, 3009507273, 3001589655, 3009649876, 3002807111, 1000116158, 1218444, 3019807891, 3002808267, 1828100, 3042990265, 3005426550, 3010703925
Wholesale access for licensed clinicians.

Free to join: your NPI is checked against the federal registry at signup, then wholesale pricing and the professional shelves open.

Data from openFDA, FDA's public API. FDA says not to rely on it to make decisions about medical care and to treat every result as unvalidated; confirm against FDA's own record and the product labeling. Not medical or legal advice.