Device recalls

Computed Tomography X-ray System, Model: uCT 530 with software

Shanghai United Imaging Healthcare Co., Ltd. · Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are…

Open, ClassifiedSoftware designZ-3277-2026
Open FDA's page for this record
Cfres ID
222317
Product res number
Z-3277-2026
Event date initiated
2026-08-11
Event date posted
2026-09-25
Recall status
Open, Classified
Res event number
99731
Product code
JAK
Product description
Computed Tomography X-ray System, Model: uCT 530 with software
Firm FEI number
3011015597
Recalling firm
Shanghai United Imaging Healthcare Co., Ltd.
Address 1
No. 2258 Chengbei Rd, Jiading Ind. Chengbei Rd
Address 2
No. 2258
City
Shanghai
Country
China
Root cause description
Software design
Product quantity
4
Code info

UDI-DI: 06971576831012. Serial Numbers/Software: 300174/R001.19.5.1839204-Re3300SP1H1_P4, 304006/R001.17.6.1607336-Re3100SP4, 304007/R001.19.4.1810621-Re3300SP1H1_P3, 304008/R001.19.4.1810621-Re3300SP1H1_P3

Reason for recall

Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.

Action

On 8/11/2026, correction notices were emailed to customers informing them that software will be released to resolve the software problem. Customers were asked to do the following: When using the Study Split function, follow the requirements below: 1) Temporarily disable the "Study Split" function. Navigate to the system configuration interface and uncheck the "Auto Study Split" option. 2) If the "Study Split" function is clinically necessary, open the system configuration interface and select "Split on PACS" instead of "Split on Local". 3) When "Auto study split" is checked, ensure that PACS (Picture Archiving and Communication System) is configured on site and auto-archive is enabled. 4) If images are found to be missing on the PA interface, immediately verify whether the corresponding image data exists in the PACS. a) If images exist in PACS: They can be retrieved from PACS for review. b) If images do not exist in PACS: Contact the firm's service engineer for assistance. For further questions, contact firm service engineer or call firm Customer Contact Center at (855) 221-1552 or 832-699-2799

Distribution pattern

US Nationwide distribution in the states of CA, PR, UT, WV, ND, NE, NC, TX, ID, LA, MT, FL, CO, IN, KY, AL, OH, MI, IA, MO, NY, NV, TN, WV, SC, WI, IL, MS, MA, NJ.

K numbers
K181414, K200016
Harmonized identifiers (openFDA)
Device name
System, X-Ray, Tomography, Computed
Medical specialty description
Radiology
Regulation number
892.1750
Device class
2
K number
K061310, K090462, K884668, K213999, K120833, K972903, K133640, K970980, K103489, K973168, K201231, K131431, K964583, K082458, K073373, K003408, K152584, K093891, K171261, K091529, K151414, K760688, K011160, K882378, K964890, K771978, K080271, K161285, K781431, K910859, K081482, K150713, K913485, K160743, K211591, K961055, K030450, K070658, K150785, K191891 +786 more
Registration number
3004962788, 3015763655, 3016248538, 3003202425, 3008632256, 3027245002, 8043933, 3016965352, 3006487372, 3010398867, 3005810333, 3017426576, 2030624, 3012957335, 3033527282, 3049422862, 3026391023, 2134243, 3002808157, 3009077524, 3008284470, 3027373189, 3018094310, 3012761544, 3008007310, 9612283, 2126677, 3004198450, 3007797756, 3019216, 1226188, 3017375271, 3002907620, 1000246715, 9613299, 3027339477, 3003575350, 9617978, 3005156333, 3008769756 +127 more
FEI number
1000139922, 3004962788, 3015763655, 3016248538, 3002619595, 3003007876, 3003202425, 3008632256, 3027245002, 3003076831, 3006487372, 3010398867, 3005810333, 3017426576, 3016965352, 3003079232, 3012957335, 3033527282, 3049422862, 3026391023, 3002808157, 3009077524, 3008284470, 3027373189, 3018094310, 3012761544, 3008007310, 2126677, 3004198450, 3007797756, 3002807903, 3019216, 3017375271, 3002907620, 1000514697, 1000246715, 3027339477, 3003575350, 3005156333, 3008769756 +127 more